Event ID — 1002
Description
A system BIOS update has been scheduled for the next reboot
Severity Information
Cause The user has chosen to update the flash basic input/output system (BIOS).
Event ID – 1003
Description
A previously scheduled system BIOS update has been canceled
Severity Information
Cause The user decides to cancel the flash BIOS update, or an error occurs during the
flash.
Event ID — 1004
Description
Thermal shutdown protection has been initiated
Severity Error
Cause This message is generated when a system is configured for thermal shutdown due
to an error event. If a temperature sensor reading exceeds the error threshold for
which the system is configured, the operating system shuts down and the system
powers off. This event may also be initiated on certain systems when a fan
enclosure is removed from the system for an extended period of time.
Event ID — 1005
Description
SMBIOS data is absent
Severity Error
Cause The system does not contain the required systems management BIOS version 2.2
or higher, or the BIOS is corrupted.
Event ID — 1006
Description
Automatic System Recovery (ASR) action was performed Action
performed was: <Action>
Date and time of action:<Date and time>
Severity Error
Cause This message is generated when an automatic system recovery action is performed
due to a hung operating system. The action performed and the time of action is
provided.
28