redundancy unit location, chassis location, previous redundancy state, and the
number of devices required for full redundancy information is provided.
Event ID — 1305
Description
Redundancy degraded Redundancy unit: <Redundancy Location in
chassis>
Chassis location: <Name of chassis>
Previous redundancy state was: <State>
Severity Warning
Cause A redundancy sensor in the specified system detected that one of the components
of the redundancy unit has failed but the unit is still redundant. The redundancy
unit location, chassis location, previous redundancy state, and the number of
devices required for full redundancy information is provided.
Event ID — 1306
Description
Redundancy lost Redundancy unit: <Redundancy Location in
chassis>
Chassis location: <Name of chassis>
Previous redundancy state was: <State>
Severity Error
Cause A redundancy sensor in the specified system detected that one of the components
in the redundant unit has been disconnected, has failed, or is not present. The
redundancy unit location, chassis location, previous redundancy state, and the
number of devices required for full redundancy are provided.
Power Supply Messages
The power supply sensors monitor how well a power supply is functioning. The power supply messages
listed provides status and warning information for power supplies present in a particular chassis.
Event ID — 1351
Description
Power supply sensor value unknown Sensor Location: <Location in
chassis>
Chassis location: <Name of chassis>
Previous redundancy state was: <State>
Power Supply type: <type of power supply>
<Additional power supply status information>
If in configuration error state:
Configuration error type:<type of configuration error>
Severity Warning
42