Dell 7.4 Life Jacket User Manual


 
Severity Informational
Cause and
Action
Cause: The power supply unit is switched off. Either a user switched off the power
supply unit or it is defective.
Action: Check if the power switch is turned off. If it is turned off, turn it on. If the
problem persists, check if the power cord is attached and functional. If the problem
is still not corrected or if the power switch is already turned on, replace the power
supply unit.
Related Alert
Information
Clear Alert Number: 2323
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
1001
Event ID — 2323
Description The power supply is switched on.
Severity OK / Normal / Informational
Cause and
Action
Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Status: Alert 2323 is a clear alert for alerts 2313 and 2322.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1001
Event ID — 2324
Description The AC power supply cable has been removed.
Severity Critical / Failure / Error
Cause and
Action
Cause: The power cable may be pulled out or removed. The power cable may also
have overheated and become warped and nonfunctional.
Action: Replace the power cable.
Related Alert
Information
Clear Alert Number: 2325
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
1004
149