SNMP Trap
Numbers
1154
Event ID — 2170
Description The controller battery charge level is normal.
Severity OK / Normal / Informational
Cause and
Action
Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID — 2171
Description The controller battery temperature is above normal.
Severity Warning / Non-critical
Cause and
Action
Cause: The battery may be recharging, the room temperature may be too hot, or
the fan in the system may be degraded or failed.
Action: If this alert was generated due to a battery recharge, the situation is
corrected when the recharge is complete. You should also check if the room
temperature is normal and that the system components are functioning properly.
Related Alert
Information
Clear Alert Number: 2172
Related Alert Number: None
Local Response Agent (LRA) Number: 2100
SNMP Trap
Numbers
1153
Event ID — 2172
Description The controller battery temperature is normal.
Severity OK / Normal / Informational
Cause and
Action
Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: Alert 2172 is a clear alert for alert 2171.
Related Alert Number: None
Local Response Agent (LRA) Number: None
98