Event ID — 1013
Description
System Peak Power detected new peak value Peak value (in
Watts): <Reading>
Severity Information
Cause The system peak power sensor detected a new peak value in power consumption.
The new peak value in Watts is provided.
Event ID — 1014
Description
System software event: <Description>
Date and time of action: <Date and time>
Severity Warning
Cause This event is generated when the systems management agent detects a critical
system software generated event in the system event log which could have been
resolved.
Event ID — 1015
Description
Server Based Management Mode is enabled
Severity Information
Cause This event is generated when the server-based management mode is enabled.
Event ID — 1016
Description
Server Based Management Mode is disabled
Severity Information
Cause This event is generated when the server-based management mode is disabled.
Temperature Sensor Messages
The temperature sensors listed help protect critical components by alerting the systems management
console when temperatures become too high inside a chassis. The temperature sensor messages use
more variables: sensor location, chassis location, previous state, and temperature sensor value or state.
Event ID — 1050
Description
Temperature sensor has failed Sensor location: <Location in
chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
30