Event ID — 2415
Description Controller battery is discharging.
Severity Informational
Cause and
Action
Cause: The battery learn cycle has started.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID — 2416
Description Disk medium error detected.
Severity Warning / Non-critical
Cause and
Action
Cause: A part of the physical disk is damaged.
Action: None.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
903
Event ID — 2417
Description There is an unrecoverable medium error detected on virtual disk.
Severity Critical / Failure / Error
Cause and
Action
Cause: Unrecoverable medium error found on one or more member physical disks
of a virtual disk.
Action: Perform a backup of the virtual disk with the Verify option selected. If the
Backup operation is successful, it indicates that the un-recoverable medium did
not affect user data.
If the Backup operation fails, restore the file from a previous backup. After restoring
the file, run check consistency operation:
• If the consistency check is successful, no further action is required.
• If the consistency check finds and unrecoverable medium error, it means that
the medium error is located in non-user data. No further action is required as,
writing data to the location of the medium error fixes the problem.
179