Dell 7.4 Life Jacket User Manual


 
Event ID — 2162
Description Communication regained.
Severity OK / Normal / Informational
Cause and
Action
Cause: Communication with an enclosure has been restored. This alert is for
informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: Alert 2162 is a clear alert for alerts 2137 and 2292.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
851
Event ID — 2163
Description Rebuild completed with errors.
Severity OK / Normal / Informational
Cause and
Action
Cause: During a rebuild one or more blocks of data was not recoverable due to
missing parity information. Some data loss may have occurred.
Action: Perform a check to verify the built array. Any files that are impacted should
be restored from a backup. See the Storage Management online help for more
information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID — 2164
Description See the Readme file for a list of validated controller driver versions.
Severity OK / Normal / Informational
Cause and
Action
Cause: Storage Management is unable to determine whether the system has the
minimum required versions of the RAID controller drivers. This alert is for
informational purposes.
Action: See the Readme file for driver and firmware requirements. In particular, if
Storage Management experiences performance problems, you should verify that
you have the minimum supported versions of the drivers and firmware installed.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
95