Event Message Severity Cause
Fan <number> RPM is
within range.
Information The speed of the specified fan is
operating in a normal range.
Fan <number> is removed.
Critical A required fan was removed.
Fan <number> was
inserted.
Information A fan was added.
Fan <number> is present.
Information The total number of fans present.
Fan <number> is absent.
Critical A required fan is missing.
The fans are redundant.
Information One or more fans may have
started functioning or installed
and the redundancy has been
regained.
Fan redundancy is lost.
Critical One or more required fans may
have failed or removed and
hence, the redundancy was lost.
Fan redundancy is
degraded.
Warning One or more fans may have
failed or removed and hence, the
redundancy has been degraded.
Processor Status Events
The processor status messages monitor the functionality of the processors in a system. These messages
provide processor health and warning information of a system.
Table 8. Processor Status Events
Event Message Severity Cause
<Processor Entity> status
processor sensor IERR,
where <Processor Entity>
is the processor that
generated the event. For
example, PROC for a
single processor system
and PROC # for
multiprocessor system.
Critical IERR internal error generated by
the <Processor Entity>. This
event is generated due to
processor internal error.
<Processor Entity> status
processor sensor Thermal
Trip.
Critical The processor generates this
event before it shuts down
because of excessive heat
caused by lack of cooling or heat
synchronization.
<Processor Entity> status
processor sensor
recovered from IERR.
Information This event is generated when a
processor recovers from the
internal error.