Dell 7.4 Life Jacket User Manual


 
If in configuration error state:
Configuration error type:<type of configuration error>
Severity Error
Cause A power supply has been disconnected or has failed. The sensor location, chassis
location, previous state, power supply type, additional power supply status, and
configuration error type information are provided.
Memory Device Messages
The memory device messages listed provides status and warning information for memory modules
present in a particular system. Memory devices determine health status by monitoring the ECC memory
correction rate and the type of memory events that have occurred.
NOTE: A critical status does not always indicate a system failure or loss of data. In some instances,
the system has exceeded the ECC correction rate. Although the system continues to function, you
should perform system maintenance as described.
NOTE: The <status> can be either critical or non-critical.
Event ID — 1400
Description
Memory device status is <status>
Memory device location: <location in chassis>
Possible memory module event cause: <list of causes>
Severity Informational
Cause Memory device monitoring has been disabled. The memory module may not be
correctly seated, wrongly configured, or has failed.
Event ID — 1401
Description
Memory device status is <status>
Memory device location: <location in chassis>
Possible memory module event cause: <list of causes>
Severity Informational
Cause Memory device status is unknown. The memory module may not be correctly
seated, wrongly configured, or has failed.
Event ID — 1402
Description
Memory device status is <status>
Memory device location: <location in chassis>
Possible memory module event cause: <list of causes>
Severity Informational