7. INITIAL SETTINGS
7-12
Air bleeding
Air bleeding can not be performed if the drive unit has not been selected.
1. Select the option for [Air Bleeding] from the [Dockside Setup] menu then push the
Course control knob.
2. Rotate the Course control knob to select [Yes] then push the knob.
The message shown below appears.
3. Press the key.
4. Remove the appropriate rudder cap of the cylinder to bleed air, then reattach the
cap.
5. Press the key.
6. Remove the appropriate rudder cap of the cylinder to bleed air, then reattach the
cap.
7. Repeat steps step 3-6 to bleed air completely.
8. Press the key to finish air bleeding.
Rudder test
The rudder test can not be performed if the drive unit has not been selected.
1. Select the option for [Rudder Test] from the [Dockside Setup] menu then push the
Course control knob.
2. Rotate the Course control knob to select [Yes] then push the knob.
The message shown below appears.
3. Center the rudder then push the Course control knob.
The message shown below appears.
4. Press the key and confirm the direction of rudder movement.
Push arrow key to enable
pumpset
Push MENU key when done
Use wheel to
center rudder before
rudder test.
Are you sure?
Yes
No
Push and hold STBD arrow
key until rudder moves.
Move Rudder
Abort