3. ALARMS
3-9
3.12.2 Wind deviation alarm
The wind deviation alarm sounds when the current wind angle is greater than the wind
angle limit set.
Note: The setting value of the wind deviation alarm can be changed, but you can not
deactivate this alarm.
1. Open the [Wind Alarm] menu.
2. Rotate the Course control knob to select the current setting value for [Wind De-
viation Alarm] then push the knob.
3. Rotate the Course control knob to set a value then push the knob.
4. Press the key four times to close the menu.
3.12.3 True and apparent wind speed alarm
The true or apparent wind speed alarm warns you when the true or apparent wind
speed is over or under the true wind speed alarm setting.
1. Open the [Wind Alarm] menu.
2. Rotate the Course control knob to select the current setting for [True Wind Spd
Alarm] (true) or [Apparent Wind Spd Alarm] (apparent) menu then push the knob.
3. Rotate the Course control knob to select [ON] then push the knob.
4. Rotate the Course control knob to select the current value then push the knob.
5. Rotate the Course control knob to set the upper and lower limits for the alarm
then push the knob.