Furuno 711c Marine Instruments User Manual


 
7. INITIAL SETTINGS
7-17
6. Rotate the Course control knob to select [Safe Helm Response] then push the
knob.
7. The cursor is selecting the current setting value for [Response]; push the Course
control knob.
8. Rotate the Course control knob to select a value then push the knob (setting
range: 1-10).
The higher the value the faster the response.
9. Press the key to close the [Safe Helm Response] window.
10. Rotate the Course control knob to select the current setting for [Safe Helm Beep]
then push the knob.
11. Rotate the Course control knob to select [ON] or [OFF] then push the knob.
[Safe Helm Beep] turns the beep on or off when the safe helm mode is activated.
12. Press the key to close the [Safe Helm/P.Assist] menu.
Power assist setup (for Accu-Steer FPS 12V (or 24V) drive)
Perform the helm sensor test before doing the power assist setup. For details of the
helm sensor test, see "Helm sensor test (for Accu-Steer FPS 12V (or 24V)
drive)" on page 7-15.
1. Select [Safe Helm/P.Assist Setup] from the [Dockside Setup] menu then push the
Course control knob.
[Safe Helm/P.Assist Setup] appears on the [Dockside Setup] menu after the helm
sensor test is successfully completed.
2. Rotate the Course control knob to select the current setting for [Power Assist]
then push the knob.
Safe Helm Response
Response: 6 PORT STBD
Turn helm to PORT/STBD to set
Safe Helm response time.
Higher value = Faster
response.
Push MENU key to return
Not shown with Fantum Feedback
TM
.
When you turn the helm,
PORT or STBD is highlighted
according to the rudder
direction.