Furuno 711c Marine Instruments User Manual


 
7. INITIAL SETTINGS
7-25
7.6 NMEA0183 Port Setup
The [NMEA0183 Setup] menu sets the NMEA0183 port according to the equipment
connected to the port. To open the [NMEA0183 Setup] menu, select [NMEA0183 Set-
up] from the [Installation Menu] window.
Note: [Port2] is not shown when [Boat Type] is set to [EVCS boat].
1. The cursor is selecting [Port1]; push the Course control knob.
2. The cursor is selecting the current name for [Naming]. This menu item lets you
change the name of the port. For example, equipment type, model number, etc.
The name can have a maximum of 14 alphanumeric characters. If you don’t need
to change the name, go to step 3.
1) Push the Course control knob.
2) Rotate the Course control knob to select character then push the knob.
3) The cursor moves to the character. Repeat step 2 to change the character.
You can select the input location with the and keys.
3. Rotate the Course control knob to select the current setting for [Output FMT]
then push the knob.
4. Rotate the Course control knob to select the output format
of the equipment then push the knob.
5. Rotate the Course control knob to select the current value
for [Baudrate] then push the knob.
6. Rotate the Course control knob to select the baud rate of the
equipment then push the knob.
NMEA0183 Setup
Port 1
Port 2
Naming: PORT1
Output FMT: NMEA0183 V3.0
Baudrate: 4800bps
Select Output Sentence
Incoming NMEA0183 Data
NMEA0183 Port1
NMEA0183 V1.5
NMEA0183 V2.0
NMEA0183 V3.0
4800bps
38400bps