Furuno 711c Marine Instruments User Manual


 
5. MAINTENANCE, TROUBLESHOOTING
5-15
0011 Bypass/clutch is shorted out.
Please turn OFF and check drive
circuit.
Bypass/clutch is shorted. Turn off power.
0013 Rudder drive error Turn off power.
0017 Rudder angle error Turn off power.
0019 EVC interface fail. System error of the IPS interface unit.
Turn off power, and then check the condi-
tion of the IPS interface unit.
0301 Communication error No communication between processor
unit and all control units. Turn off power.
Notice
2001 Input voltage is under limit Input voltage under limit. Check power
supply.
2003 Input voltage is over limit Input voltage over limit. Check power sup-
ply.
2101 NAV mode parameter error Invalid parameter entered in NAV mode.
Reenter parameter.
2105 Start to turn by fishing mode Boat is starting to turn after dodge opera-
tion.
2107 Circle mode stopped Circle mode was stopped.
2109 Mode was changed. Steering mode changed.
2201 Warning. Remote controller’s
SW is ON
Remote controller switch is ON. Turn it
OFF to continue operation.
2301 Heading source are changed. Heading source changed.
2303 Wind source are changed. Wind source changed.
2305 Position source are changed. Position source changed.
2307 Speed source are changed. Source of speed changed.
2330 Arrived at waypoint Arrival alarm alerts you to arrival at final
waypoint.
2340 Waypoint was changed Switching to next waypoint.
2360 No water temp data Check water temperature sensor.
2362 No depth data Check depth sensor.
2401 The preset time passed. The watch alarm has activated. Operate
any key to confirm presence.
2370 Helm Sensor error Check helm sensor.
2801 EVC Override The OVRD mode is enabled.
2901 No compass adjustment Check heading sensor.
Error
no.
Error message Meaning, remedy