7. INITIAL SETTINGS
7-16
6. Push the Course control knob to show the helm sensor test result.
7. Press the key to finish the helm sensor test.
Safe helm setup (for Accu-Steer FPS 12V (or 24V) drive)
Perform the helm sensor test before doing the safe helm setup. For details of the helm
sensor test, see "Helm sensor test (for Accu-Steer FPS 12V (or 24V)
drive)" on page 7-15.
1. Select [Safe Helm/P.Assist Setup] from the [Dockside Setup] menu then push the
Course control knob.
[Safe Helm/P.Assist Setup] appears on the [Dockside Setup] menu after the helm
sensor test is successfully completed.
2. Rotate the Course control knob to select the current setting for [Safe Helm] then
push the knob.
3. Rotate the Course control knob to select [ON] then push the knob to activate the
safe helm.
4. Rotate the Course control knob to select the current setting value for [Return De-
lay] then push the knob.
5. Rotate the Course control knob to set a value for [Return Delay] then push the
knob (setting range: 1-20 sec.).
NAV mode: When the data from the helm sensor is not input for the set time,
NAV mode is restored.
Other than NAV mode): When cruising straight ahead and the data from the
helm sensor is not input for the set time, the previous steering mode is restored.
Universal Input1: STBD*
Universal Input2: PORT*
Helm Sensor Test
Push MENU key to return.
Not shown with Fantum Feedback
TM
.
*: “--” appears if the test failed.
Safe Helm: ON Return Delay 5 sec
Safe Helm Response
Safe Helm Beep: ON
Power Assist: OFF
Safe Helm/P.Assist Setup