Schneider Electric Altivar 12 Outboard Motor User Manual


 
BBV28581 05/2010 123
Parameter index
Code Page Name Unit Possible value / Function Factory setting
User
setting
CL2
88
Current limitation 2 A
0.25 to 1.5
-1.5 A
COd 43
HMI Password -
OFF
On
Code disabled
Code activated
OFF
COM1 42
Modbus communication status -
r0t0
rOt1
r1t0
r1t1
--
COS 57
Rated motor cos phi - 0.5 to 1 -
according to
drive rating
CrH1 52
AI1 current scaling parameter
of 100%
mA 0 to 20 -20 mA
CrL1 52
AI1 current scaling parameter
of 0%
mA 0 to 20 -4 mA
Ctd 55
Motor current threshold In 0 to 1.5 -InV
Ctt 57
Motor control type -
Std
PErF
PUMP
Standard
Performance
Pump
Std
dCF 66
Ramp divider 1 to 10 -4
dE2 65 Deceleration 2 s
0.0 to
999.9
-5 s
dEC
45
64
Deceleration s
0.0 to
999.9
- 3.0 s
dP1 42 Last detected fault 1 - see page 107 --
dP2 42
Last detected fault 2 - see page 107 --
dP3 43
Last detected fault 3 - see page 107 --
dP4 43
Last detected fault 4 - see page 107 --
drn
96 Degraded line supply operation
nO
YES
No
Yes
nO
EP1
42
State of drive at detected fault 1 - - - - -
EP2
43
State of drive at detected fault 2 - - - - -
EP3
43
State of drive at detected fault 3 - - - - -
EP4
43
State of drive at detected fault 4 - - - - -