Schneider Electric Altivar 12 Outboard Motor User Manual


 
64 BBV28581 05/2010
Configuration Mode - Complete menu (FULL)
Code
Name/Description Adjustment range Factory setting
FUn-
Function menu
rPt-
Ramp menu
ACC
T
M Acceleration
0.0 s to 999.9 s
3.0 s
Acceleration time between 0 Hz and the Rated motor frequency FrS page 57.
Make sure that this value is compatible with the inertia being driven.
dEC
T
M Deceleration
0.0 s to 999.9 s
3.0 s
Time to decelerate from the Rated motor frequency FrS page 57 to 0 Hz
Make sure that this value is compatible with the inertia being driven.
rPt
M Ramp shape assignment
Lin
LIn
S
U
T
v Linear
v S shape
v U shape
S shape
U shape
The rounding coefficient is fixed,
t1 = 0.6 set ramp time (linear)
t2 = 0.4 set ramp time (round)
t3 = 1.4 set ramp time
The rounding coefficient is fixed,
t1 = 0.5 set ramp time (linear)
t2 = set ramp time (round)
t3 = 1.5 set ramp time
rPS
M Ramp switching commutation
nO
nO
LIH
L2H
L3H
L4H
LIL
L2L
L3L
L4L
v Not assigned
v L1H: LI1 active High
v L2H: LI2 active High
v L3H: LI3 active High
v L4H: LI4 active High
v L1L: LI1 active low
v L2L: LI2 active low
v L3L: LI3 active low
v L4L: LI4 active low
See LI assignment information on page 46.
T
Parameter that can be modified during operation or when stopped.
I-O-
drC-
CtL-
FUN-
FLt-
COM-