Schneider Electric Altivar 12 Outboard Motor User Manual


 
BBV28581 05/2010 129
Parameter index
Code Page Name Unit Possible value / Function Factory setting
User
setting
rP2
73
2 preset PID reference % 0 to 100 -25%
rP3
73
3 preset PID reference % 0 to 100 -50%
rP4
73
4 preset PID reference % 0 to 100 -75%
rPC
39
PID reference - - - - -
rPE
39
PID error - - - - -
rPF
39
PID Feedback - - - - -
rPG
72
PID proportional gain 0.01 to 100 -1
rPH
73
PID max value reference % PID 0 to 100 - 100%
rPI
73
Internal PID reference % PID 0 to 100 -0%
rPL
73
PID min value reference % PID 0 to 100 -0%
rPr
96
Reset power run
nO
FtH
Function inactive
Reset fan time display
nO
rPS 64
Ramp switching
commutation
nO
L1H
L2H
L3H
L4H
L1L
L2L
L3L
L4L
No
L1h: LI1 active high
L2h: LI2 active high
L3h: LI3 active high
L4h: LI4 active high
L1L: LI1 active low
L2L: LI2 active low
L3L: LI3 active low
L4L: LI4 active low
nO
rPt 64
Ramp shape assignment
LIn
S
U
Linear
S shape
U shape
LIn
rrS 66
Reverse direction -
nO
LIh
L2H
L3H
L4H
Function inactive
L1h active high
L2h active high
L3h active high
L4h active high
nO
rSF
91
Detected fault reset
assignment
-
nO
L1H
L2H
L3H
L4H
No
L1h: LI1 active high
L2h: LI2 active high
L3h: LI3 active high
L4h: LI4 active high
nO
rSL
75
PID wake up level % 0 to 100 -0%
rtHI
42
Run elapsed time display 0.01h 0.01 to 999 ---
SCS 46
Store customer parameter
set
-
nO
Str1
No
Yes
nO
SdC1 67
Automatic DC injection
current
A 0 to 1.2 0.7 A
SFr 59
Switching frequency kHz 2 to 16 -12
SFS
73
PID predictive speed - nO to 400 -nO
SFt 59
Switching frequency type -
HF1
HF2
HF1
HF2
HF1