HP (Hewlett-Packard) E1412A Waterskis User Manual


 
102 Multimeter Command Reference Chapter 3
:CURRent:AC?
MEASure:CURRent:AC? [<range>|MIN|MAX|DEF|AUTO
[,<
resolution>|MIN|MAX|DEF]] selects the AC current function and allows you to
specify the measurement range and resolution (see range versus resolution table at
start of chapter).
Parameters
Comments To select a standard measurement range, specify range as the input signal’s
maximum expected current. The multimeter then selects the correct range that
will accept the input.
The AUTO or DEFault option for the range parameter enables autorange.
The MIN and MAX parameters select the minimum or maximum values for
range and resolution:
For range:
MIN = 1A; MAX = 3A
For resolution: see Table 3-5 on page 71 for resolution choices.
To select autorange, specify DEF for range or do not specify a value for the
parameter. In the autorange mode, the multimeter samples the input signal
before each measurement and selects the appropriate range.
To specify a MIN or MAX resolution while autoranging, you must specify the
AUTO or DEFault parameter for the range parameter as
MEAS:CURR:AC? DEF (you cannot omit the range parameter). This prevents
the
MIN or MAX resolution from being interpreted as a range setting and the
resulting command becomes
MEAS:CURR:AC? DEF,MIN or
MEAS:CURR:AC? DEF,MAX (or use AUTO in place of DEF).
Related Commands: FETCh?, INITiate, READ?
Example Making AC Current Measurements
MEAS:CURR:AC? 1,MAX
Function: AC Current; range selected: 1A;
MAX resolution: 1.0E-04 A.
Parameter Name Parameter Type Range of Values Default Units
<
range>
numeric 1A|3A|
MIN|MAX|DEF|AUTO
A
<resolution>
numeric
resolution|
| MIN | MAX | DEF
A