HP (Hewlett-Packard) E1412A Waterskis User Manual


 
Multimeter Command Reference 169Chapter 3
Command Description
[SENSe:] FUNCtion “function
FUNCtion?
CURRent:AC:RANGe <range>|MIN|MAX
CURRent:AC:RANGe? [MIN|MAX]
CURRent:AC:RANGe:AUTO OFF|ON
CURRent:AC:RANGe:AUTO?
CURRent:AC:RESolution <resolution> |MIN|MAX
CURRent:AC:RESolution? [MIN|MAX]
CURRent[:DC]:APERture .333ms|3.33ms|16.7ms|
167ms|1.67s|MIN|MAX
CURRent[:DC]:APERture? [MIN|MAX]
CURRent[:DC]:NPLCycles .02|.2|1|10|100|MIN|MAX
CURRent[:DC]:NPLCycles? [MIN|MAX]
CURRent[:DC]:RANGe <range>|MIN|MAX
CURRent[:DC]:RANGe? [MIN|MAX]
CURRent[:DC]:RANGe:AUTO OFF|ON
CURRent[:DC]:RANGe:AUTO?
CURRent[:DC]:RESolution <resolution>|MIN|MAX
CURRent[:DC]:RESolution? [MIN|MAX]
DETector:BANDwidth 3|20|200|MIN|MAX
DETector:BANDwidth? [MIN|MAX]
FREQuency:APERture 0.01|0.1|1|MIN|MAX
FREQuency:APERture? [MIN|MAX]
FREQuency:VOLTage:RANGe <range>|MIN|MAX
FREQuency:VOLTage:RANGe? [MIN|MAX]
FREQuency:VOLTage:RANGe:AUTO OFF|ON
FREQuency:VOLTage:RANGe:AUTO?
FRESistance:APERture .333ms|3.33ms|16.7ms|
167ms|1.67s|MIN|MAX
FRESistance:APERture? [MIN|MAX]
FRESistance:NPLCycles 0.02|0.2|1|10|100|MIN|MAX
FRESistance:NPLCycles? [MIN|MAX]
FRESistance:RANGe <range>|MIN|MAX
FRESistance:RANGe? [MIN|MAX]
FRESistance:RANGe:AUTO OFF|ON
FRESistance:RANGe:AUTO?
FRESistance:RESolution <resolution>|MIN|MAX
FRESistance:RESolution? [MIN|MAX]
PERiod:APERture 0.01|0.1|1|MIN|MAX
PERiod:APERture? [MIN|MAX]
PERiod:VOLTage:RANGe <range>|MIN|MAX
PERiod:VOLTage:RANGe? [MIN|MAX]
PERiod:VOLTage:RANGe:AUTO OFF|ON
PERiod:VOLTage:RANGe:AUTO?
RESistance:APERture .333ms|3.33ms|16.7ms|167ms|
1.67s|MIN|MAX
RESistance:APERture? [MIN|MAX]
RESistance:NPLCycles 0.02|0.2|1|10|100|MIN|MAX
RESistance:NPLCycles? [MIN|MAX]
RESistance:RANGe <range>|MIN|MAX
RESistance:RANGe? [MIN|MAX]
RESistance:RANGe:AUTO OFF|ON
RESistance:RANGe:AUTO?
RESistance:RESolution <resolution>|MIN|MAX
RESistance:RESolution? [MIN|MAX]
Select measurement function.
Query measurement function.
Set range.
Query range.
Enable/disable autoranging.
Query autorange mode.
Set resolution.
Query resolution.
Set the integration time in seconds.
Query integration time (seconds).
Set integration time in PLCs.
Query integration time (PLCs).
Set range.
Query range.
Enable/disable autoranging.
Query autorange mode.
Set resolution.
Query resolution.
Set the AC filter.
Query AC filter.
Set integration time in seconds.
Query aperture (integration) time.
Select range.
Query range.
Enable/disable autoranging.
Query autorange mode.
Set integration time in seconds.
Query integration time (seconds).
Set integration time in PLCs.
Query integration time (PLCs).
Select range.
Query range.
Enable/disable autoranging.
Query autorange mode.
Specify resolution.
Query resolution.
Set integration time in seconds.
Query integration time (seconds).
Select range.
Query range.
Enable/disable autoranging.
Query autorange mode.
Set integration time in seconds.
Query integration time (seconds).
Set integration time in PLCs.
Query integration time (PLCs).
Set range.
Query range.
Set autorange mode.
Query autorange mode.
Specify resolution.
Query resolution.