168 Multimeter Command Reference Chapter 3
Command Description
CONFigure :CURRent:AC [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
:CURRent[:DC] [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
:FREQuency [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
:FRESistance [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
:PERiod [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
:RESistance [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
:VOLTage:AC [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
[:VOLTage[:DC]] [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
[:VOLTage[:DC]]:RATio [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]
Configure multimeter for AC current.
Configure multimeter for DC current.
Configure multimeter for frequency.
Configure multimeter for 4-wire ohms.
Configure multimeter for period.
Configure multimeter for 2-wire ohms.
Configure multimeter for AC voltage.
Configure multimeter for DC voltage.
Configure multimeter for DC voltage ratio.
CONFigure? Query multimeter configuration.
DATA :POINts? Query number of readings stored in the
multimeter’s memory.
FETCh? Place stored readings in output buffer.
INITiate [:IMMediate] Place multimeter in wait-for trigger state.
INPut :IMPedance:AUTO 1|0|ON|OFF
:IMPedance:AUTO?
Enable/disable auto impedance mode.
Query impedance mode.
MEASure :CURRent:AC? [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
:CURRent[:DC]? [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
:FREQuency? [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
:FRESistance? [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
:PERiod? [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
:RESistance? [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
:VOLTage:AC? [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
[:VOLTage[:DC]]? [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
[:VOLTage[:DC]]:RATio? [<range>|MIN|MAX|DEF|AUTO
[,<resolution>|MIN|MAX|DEF]]
Make an AC current measurement.
Make a DC current measurement.
Make a frequency measurement.
Make a 4-wire ohms measurement.
Make a period measurement.
Make a 2-wire ohms measurement.
Make an AC voltage measurement.
Make a DC voltage measurement.
Make a DC voltage ratio measurement.
OUTPut :TTLTrg0|1|2|3|4|5|6|7[:STATe]1|0|ON|OFF
:TTLTrg0|1|2|3|4|5|6|7[:STATe]?
Send voltmeter complete to VXIbus trigger lines.
Query voltmeter complete destination.
READ? Place multimeter in wait-for-trigger state; place
readings in output buffer.
SAMPle :COUNt 1-50000|MIN|MAX
:COUNt? [MIN|MAX]
Set number of readings per trigger.
Query number of readings per trigger.