Enable Linking Across Selected Galileos
Replicates these settings across all selected Galileos when Global Galileo Select-Linking
Mode (p. 78) is enabled.
Input Channel Types:
A Galileo can accept up to six analog inputs or three digital (AES/EBU) inputs. These inputs
are named in stereo pairs (A/B; C/D; E/F).
Analog / AES
Configures the input for analog input or AES digital input.
The image displaying the three XLR input pairs on the back of the Galileo indicates which
connectors are enabled. When using AES/EBU input, the bottom connector is not available
for use.
Input Voltage Range:
Enabled for analog inputs only.
+26 dBu / +20 dBu
+26 dBu is standard signal level for analog input.
+20 dBu may be useful as a studio mode. This setting may cause clipping or increase noise
levels. Use with caution!
Set all to +26 dBu / Set all to +20 dBu
Provides a shortcut to set all input voltages to the same range.
Output Voltage Range:
+26 dBu / +20 dBu
+26 dBu is standard signal level for analog output.
+20 dBu may be useful as a studio mode. This setting may cause clipping or increase noise
levels. Use with caution!
Set all to +26 dBu / Set all to +20 dBu
Provides a shortcut to set all output voltages to the same range.
104
CHAPTER 4: USER INTERFACE REFERENCE