Cisco Systems MDS 9000 Marine Radio User Manual


 
20-72
Cisco MDS 9000 Family Command Reference
78-16088-01, Cisco MDS SAN-OS Release 1.3
Chapter 20 Show Commands
show incompatibility system
show incompatibility system
To display the HA compatibility status between the two supervisor modules, use the show
incompatibility system command.
show incompatibility system [bootflash: | slot0: | volatile:]image-filename
Syntax Description
Defaults None.
Command Modes EXEC
Command History This command was introduced in Cisco MDS SAN-OS Release 1.2(1).
Usage Guidelines If the HA compatibility is
strict on an active supervisor module, the standby supervisor module
synchronization may not succeed and may move into an inconsistent state.
If the HA compatibility is
loose, the synchronization may happen without errors, but some resources
may become unusable when a switchover happens.
Examples The following examples display kernel core settings.
switch# show incompatibility system bootflash:old-image-y
The following configurations on active are incompatible with the system image
1) Feature Index : 67 , Capability : CAP_FEATURE_SPAN_FC_TUNNEL_CFG
Description : SPAN - Remote SPAN feature using fc-tunnels
Capability requirement : STRICT
2) Feature Index : 119 , Capability : CAP_FEATURE_FC_TUNNEL_CFG
Description : fc-tunnel is enabled
Capability requirement : STRICT
bootflash: Source or destination location for internal bootflash memory
slot0: Source or destination location for the CompactFlash memory or PCMCIA
card.
volatile: Source or destination location for the volatile directory.
image-filename Specifies the name of the system or kickstart image.