Hitachi L200 Marine Battery User Manual


 
“B” Group: Fine Tuning Functions
Configuring
Drive Parameters
3–34
Overload Restriction
If the inverter’s output current exceeds a
preset current level you specify during
acceleration or constant speed, the overload
restriction feature automatically reduces the
output frequency to restrict the overload.
This feature does not generate an alarm or
trip event. You can instruct the inverter to
apply overload restriction only during
constant speed, thus allowing higher
currents for acceleration. Or, you may use
the same threshold for both acceleration and
constant speed.
When the inverter detects an overload, it
must decelerate the motor to reduce the
current until it is less than the threshold.
You can choose the rate of deceleration that
the inverter uses to lower the output current.
Motor
Current
Output
frequency
t
t
Restriction area
0
0
B022
B023
“B” Function
Run
Mode
Edit
Defaults
Func.
Code
Name /
SRW Display
Description
–FEF
(EU)
–FU
(USA)
Units
B021 Overload restriction
operation mode
Select the operating mode
during overload conditions,
three options, option codes:
00...Disabled
01...Enabled for acceleration
and constant speed
02...Enabled for constant
speed only
01 01
OL Mode ON
B022 Overload restriction
setting
Sets the level for overload
restriction, between 20% and
150% of the rated current of
the inverter, setting resolution
is 1% of rated current
Rated current x
1.5
A
OL LVL 002.40A
B023 Deceleration rate at
overload restriction
Sets the deceleration rate when
inverter detects overload, range
is 0.1 to 30.0, resolution is 0.1.
1.0 30.0 sec.
OL Cnst 0001.0s