![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/8/8c/88c27a90-bf45-4e72-ba4e-54327bae02eb/88c27a90-bf45-4e72-ba4e-54327bae02eb-bg1c.png)
L200 Inverter Specifications
Getting Started
1–8
Item 400V Class Specifications
L200 inverters,
400V models
EU version 004HFEF 007HFEF 015HFEF 022HFEF
USA version 004HFU 007HFU 015HFU 022HFU
Applicable motor size *2 kW 0.4 0.75 1.5 2.2
HP 1/2 1 2 3
Rated capacity (460V) kVA 1.1 1.9 2.9 4.2
Rated input voltage *6 3-phase: 380 to 480V ±10%, 50/60 Hz ±5%
Integrated EMC
filter
EU version Three phase filter, Category C3 *5
USA version —
Rated input current (A) 2.0 3.3 5.0 7.0
Rated output voltage *3 3-phase: 380 to 480V (proportional to input voltage)
Rated output current (A) 1.5 2.5 3.8 5.5
Starting torque *7 100% at 6Hz
Braking Dynamic
braking, approx.
% torque (short
time stop from
50 / 60 Hz) *8
50%: ≤ 60Hz 20%: ≤ 60Hz
Capacitive feedback type, dynamic braking unit and braking
resistor optional, individually installed
DC braking Variable operating frequency, time, and braking force
Weight
EU version
(-HFEF
kg 1.4 1.8 1.9 1.9
lb 3.09 3.97 4.19 4.19
US version
(-HFU)
kg 1.3 1.7 1.8 1.8
lb 2.87 3.75 3.97 3.97