Schneider Electric HRB1684301-01 Marine Instruments User Manual


 
120 HRB1684301-01
Chapter 13—Power quality PowerLogic™ PM5500 series user manual
2. Navigate to Harm > Crest. The Crest factor information displays.
3. Press to return to the main display screens.
NOTE: Your meter’s Modbus map includes registers for harmonics data for
integration into your power or energy management system.
Related topics
See “Front panel display and meter setup” on page 31 for front panel menu
navigation details.
Search your meter’s Modbus register list at www.schneider-electric.com to
download the Modbus map.
Viewing THD/thd using the front panel
You can view THD/thd data using the front panel.
1. Navigate to THD. On the THD/thd Select screen, press THD to display values that
use the calculation method based on the fundamental harmonic, or thd to display
values that use the calculation method based on the RMS value of all harmonics in
that phase (including the fundamental).
2. Press the current or voltage THD or thd values you want to view. The total harmonic
distortion percentage values are displayed.
3. Press to return to the main display screens.
NOTE: Your meter’s Modbus map includes registers for total harmonic distortion data
for integration into your power or energy management system.
Related topics
See “Front panel display and meter setup” on page 31 for front panel menu
navigation details.
Search your meter’s Modbus register list at www.schneider-electric.com to
download the Modbus map.
K-F B K-F B K factor for phase B
K-F C K-F C K factor for phase C
Crest Factor display screens
IEEE mode IEC mode Description
V L-L U Crest factor data for line-to-line voltage
V L-N V Crest factor data for line-to-neutral voltage
Amps I Crest factor data for current
Power Quality display screens (Continued)
IEEE mode IEC mode Description
THD (or thd) display screens
IEEE mode IEC mode Description
Amps I Total harmonic distortion data for per phase and neutral currents.
V L-L U Total harmonic distortion data line-to-line voltage.
V L-N V Total harmonic distortion data line-to-neutral voltage.