Emerson Process Management 3144P Marine Instruments User Manual


 
Reference Manual
00809-0100-4021, Rev DA
November 2004
Rosemount 3144P
6-4
Certified SIS
375 FIELD
COMMUNICATOR
The Menu Tree and Fast Key sequences assume that Dev v1, DD v2 (for SIS)
is being used.
3144P SIS Menu Tree Figure 6-2 displays a complete 3144P SIS menu tree for use with the 375
Field Communicator. Options listed in bold type indicate that a selection
provides other options. For the 3144P transmitter, see “Menu Tree” on
page 3-3.
Figure 6-2. 3144P SIS Safety Certified Menu Tree
NOTE
The review menu
lists all of the
information
stored in the
3144P. This
includes device
information,
measuring
element, output
configuration, and
software revision.
1. TEST DEVICE
2. CALIBRATION
Online Menu
1. Snsr 1
2. Snsr 2
3. Terminal
4. Diff.
5. Avg
6. First Good
1. Snsr inp trim
2. Snsr trim-fact
3. Active Calibrator
1. Loop Test
2. Self test
3. Master Reset
4. Status
5. View Log
6. Clear Log
1. SNSR TRIM
2. D/A trim
3. Scaled D/A trim
1. PROCESS
VARIABLE
2. DIAGNOSTICS
AND SERVICE
3. CONFIGURATION
4. REVIEW
1. VARIABLE
MAPPING
2. SENSOR
CONFIGURATION
3. DUAL-SENSOR
CONFIGURATION
4. DEV OUTPUT
CONFIGURATION
5. DEVICE
INFORMATION
6. MEASUREMENT
FILTERING
1. Device Variables
2. PV is
3. PV Digital
4. PV AO
5. PV% rnge
6. PV LRV
7. PV URV
8. PV LSL
9. PV USL
10.PV Damp
1. DEVICE SETUP
2. PV is
3. PV
4. AO
5. % RNGE
6. PV LRV
7. PV URV
1. PV is
2. SV is
3. TV is
4. QV is
5. Variable re-map
1. Chng Type/Conn
2. Show Type/Conn
3. Sensor 1 Setup
4. Sensor 2 Setup
5. Term Temp Setup
1. PV RANGE
VALUES
2. ALARM
SATURATION
3. HART OUTPUT
4. LCD DISPLAY
OPTIONS
1. AO alrm type
2. AO Levels
3. Non-PV Alarms
1. Poll addr
2. Num req preams
3. Burst mode
4. Burst option
1. Meter Configuration
2. Meter Decimal Point
3. Meter Bar Graph
1. Tag
2. Date
3. Descriptor
4. Message
5. Final Assembly number
1. 50/60 Hz Filter
2. Intermit Detect
3. Intermit Thresh
4. Open Sensor
Holdoff
1. PV LRV
2. PV URV
3. PV Damping
4. PV Units
5. PV LSL
6. PV USL
7. PV Min. Span
1. Low Alarm
2. High Alarm
3. Low Sat.
4. High Sat.
5. Preset Alarms
1. Sensor 1
2. Sensor 2
1. Snsr 1 Units
2. Snsr 1 damp
3. Snsr 1 S/N
4. Snsr 1 LSL
5. Snsr 1 USL
6. 2-Wire Offset
1. Snsr 2 Units
2. Snsr 2 damp
3. Snsr 2 S/N
4. Snsr 2 LSL
5. Snsr 2 USL
6. 2-Wire Offset
1. Terminal Units
2. Terminal Damp
3. Terminal LSL
4. Terminal USL
1. Diff Config
2. Avg Config
3. First Good Config
4. Config Hot Backup
5. Drift Alert
1. Diff Units
2. Diff Damp
3. Diff LSL
4. Diff USL
1. Avg Units
2. Avg Damp
3. Avg LSL
4. Avg USL
1. First Good Units
2. First Good Damp
3. First Good LSL
4. First Good USL
1. Drift Alert option
2. Drift Limit
3. Drift Damping
1. Revision #s
2. Dynamic Variables
3. Device Variables
4. Sensor Variables
5. Other Variables
1. Microboard
2. A/D ASIC
3. Operation
4. Summary Byte
5. Sensor Information
1. Review PV
2. Review SV
3. Review TV
4. Review QV
1. Sensor 1
2. Sensor 2
3. Term Temp
4. Differential Temp
5. Average Temp
6. First Good
1. Review Snsr1
2. Review Snsr2
1. Universal rev
2. Field Dev Rev
3. Software Rev
4. Hardware