Emerson Process Management 3144P Marine Instruments User Manual


 
Reference Manual
00809-0100-4021, Rev DA
November 2004
Rosemount 3144P
B-6
ROSEMOUNT 3144P WITH FOUNDATION FIELDBUS
Approved Manufacturing
Locations
Rosemount Inc. – Chanhassen, Minnesota, USA
Rosemount Temperature GmbH – Germany
Emerson Process Management Asia Pacific – Singapore
European Union
Directive Information
The EC declaration of conformity for all applicable European at
www.rosemount.com. A hard copy may be obtained by contacting your local
sales representative.directives for this product can be found on the
Rosemount website
ATEX Directive (94/9/EC)
Rosemount Inc. complies with the ATEX Directive.
Electro Magnetic Compatibility (EMC) (89/336/EEC)
EN 50081-1: 1992; EN 50082-2:1995; EN 61326-1:1997 – Industrial
Hazardous Locations
Installations
North American Certifications
Factory Mutual (FM) Approvals
I5 FM Intrinsic Safety / FISCO and Non-incendive
Intrinsically Safe / FISCO for use in Class I, II, III, Division 1, Groups A,
B, C, D, E, F, and G;
Temperature code: T4 (T
amb
= – 60 °C to 60 °C)
Zone marking: Class I, Zone 0, AEx ia IIC T4 (T
amb
= – 50 °C to 60 °C)
Intrinsically safe when installed in accordance with control drawing
003144-5075.
Non-incendive for use in Class, Division 2, Groups A,B,C and D; Suitable
for use in Class II/III, Division 2, Groups F and G Non-incendive when
installed in accordance with Rosemount drawing 03144-5075.
Temperature Class: T6 (T
amb
= – 60 °C to 50 °C);
T5 (T
amb
= – 60 °C to 75 °C)
E5 Explosion Proof for Class I, Division 1, Groups A, B, C, and D.
Dust Ignition-Proof for use in Class II/III, Division 1, Groups E, F, and G.
Explosion-Proof and Dust Ignition-Proof when installed in accordance
with Rosemount drawing 03144-0320. Indoor and outdoor use. NEMA
Type 4X.
Temperature code: T5 (T
amb
= – 50 to 85 °C)
NOTE
For Group A, seal all conduits within 18 inches of enclosure; otherwise,
conduit seal not required for compliance with NEC 501-5a(1).
Non-incendive for use in Class I, Division 2, Groups A, B, C, and D.
Suitable for use in Class II/III, Division 2, Groups F and G. Non-incendive
when installed in accordance with Rosemount drawing 03144-5075.