Emerson Process Management 3144P Marine Instruments User Manual


 
Reference Manual
00809-0100-4021, Rev DA
November 2004
Rosemount 3144P
3-36
HART
Table 3-2. 375 Field Communicator Error Warning Descriptions – HART
(1)
Message Description
Add item for ALL device types or only for
this ONE device type
Asks the user whether the hot key item being added should be added for all device types or only
for the type of device that is connected.
Command not implemented The connected device does not support this function.
Communication error Either a device sends back a response indicating that the message it received was unintelligible,
or the 375 Field Communicator cannot understand the response from the device.
Configuration memory not compatible
with connected device
The configuration stored in memory is incompatible with the device to which a transfer has been
requested.
Device busy The connected device is busy performing another task.
Device disconnected Device fails to respond to a command.
Device write protected Device is in write-protect mode. Data can not be written.
Device write protected. Do you still want
to shut off?
Device is in write-protect mode. Press YES to turn the 375 Field Communicator off and lose the
unsent data.
Display value of variable on hot key
menu?
Asks whether the value of the variable should be displayed adjacent to its label on the hot key
menu if the item being
added to the hot key menu is a variable.
Download data from configuration
memory
to device
Prompts user to press SEND softkey to initiate a memory to device transfer.
Exceed field width Indicates that the field width for the current arithmetic variable exceeds the device-specified
description edit format.
Exceed precision Indicates that the precision for the current arithmetic variable exceeds the device-specified
description edit format.
Ignore next 50 occurrences of status? Asked after displaying device status. Softkey answer determines whether next 50 occurrences of
device status will be ignored
or displayed.
Illegal character An invalid character for the variable type was entered.
Illegal date The day portion of the date is invalid.
Illegal month The month portion of the date is invalid.
Illegal year The year portion of the date is invalid.
Incomplete exponent The exponent of a scientific notation floating point variable
is incomplete.
Incomplete field The value entered is not complete for the variable type.
Looking for a device Polling for multidropped devices at addresses 1–15.
Mark as read
only variable on
hotkey menu?
Asks whether the user should be allowed to edit the variable from the hotkey menu if the item
being added to the hotkey menu is
a variable.
No device configuration in configuration
memory
There is no configuration saved in memory available to
re-configure off-line or transfer to a device.
No device found Poll of address zero fails to find a device, or poll of all addresses fails to find a device if auto-poll
is enabled.
No hotkey menu available for this device. There is no menu named “hotkey” defined in the device description for this device.
No offline
devices available
There are no device descriptions available to be used to configure a device offline.
No simulation
devices available
There are no device descriptions available to simulate a device.
No UPLOAD_VARIABLES in ddl for this
device
There is no menu named “upload_variables” defined in the
device description for this device. This menu is required for
offline configuration.
No valid items The selected menu or edit display contains no valid items.
OFF KEY DISABLED Appears when the user attempts to turn the 375 Field Communicator off before sending modified
data or before completing a method.
Online device disconnected with unsent
data. RETRY or OK to lose data
There is unsent data for a previously connected device. Press RETRY to send data, or press OK
to disconnect and lose
unsent data.