Switch Fabric
Full digital, nonblocking
Electrical
10 Watts (35 BTU/hour) per 400 module, normal and maximum power consumption
Specifications
65 Watts (225 BTU/hour) per 206 module during normal operation
100 Watts (350 BTU/hour) per 206 module during maximum power consumption
U.S., Canada, and other 110V countries: 8 Amps maximum current at full system capacity (two
carriers with processor module and four 206 modules each)
Countries using 220V: 4.4 Amps maximum current (two carriers with processor module and four
206 modules each)
4-day memory backup (96 hours)
Primary
68000 microprocessor, 256Kbytes RAM, 512Kbytes ROM
Processor Module
Specifications
Expansion
8051 microprocessor, 12mHz, 8Kbytes ROM
Processor Module
Specifications
Extension Jack
Ringing voltage: +5VDC, -140 VDC peak to peak; trapezoidal wave shaping
Specifications
35- to 38-Volt talk battery
Ringing frequency: 20 Hz
PAGE Jack
Draws current on inner wire pair
Specifications
Provides contact closure on outer wire pair
600 Ohm impedance
SMDR Output
1200 baud
Format
No parity
8 data bits
2 stop bits
XON/XOFF protocol
Carriage return
Line feeds
Environmental
Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required)
Requirements—
Control Unit
Locate within 5 feet (1.5 meters) of the network interface jacks and a properly grounded
electrical outlet not controlled by a switch, using supplied 7-foot (2.1-meter) cords
Mount the Expansion Carrier at least 6” and not more than 24” away from the Primary Carrier
Operating temperature 32° to +104°F (0° to +40°C), not in direct sunlight
Humidity 15%–90%, noncondensing
For proper ventilation and easy replacement of modules, provide at least 6“ (15.2 cm) clearance
at the top and sides and 2 feet (0.6 meters) at the front and bottom of the control unit.
Locate in an area free of excess moisture, corrosive gases, dust, and chemicals
A-2