135
Function assignment of external
terminal and control
4
PARAMETERS
(2) Response time of each signal
⋅ The response time of the X10 signal is within 2ms. However, when the X10 signal is not assigned at the Pr. 30
Regenerative function selection setting of "2" (FR-HC/MT-HC/FR-CV connection), the response time of the MRS
signal is within 2ms.
Pr. 17 MRS input selection is invalid.
Pr. 30
Setting
MRS
Assignment
X10
Assignment
Response Time
Pr. 17
MRS X10
2
× Within 2ms ⎯ Invalid
× ⎯ Within 2ms ⎯
Within 20ms Within 2ms Valid
Other than 2
× Within 20ms ⎯ Valid
× ⎯⎯⎯
Within 20ms ⎯ Valid