Mitsubishi Electronics FR-F720P Marine Battery User Manual


 
367
Options and products available on the market
* Rated power consumption. The power supply specifications of the FR series manual controllers and speed controllers are 200VAC 50Hz, 220/
220VAC 60Hz, and 115VAC 60Hz.
Commercially available products (as of Jan. 2010)
Blade terminals
Commercially available products (as of Jan. 2010)
·Phoenix Contact Co.,Ltd.
·NICHIFU Co.,Ltd.
Use shielded or twisted cable as the connection cable for the control circuit terminals. Separate the cable from the main
circuit and the high-power circuits (including the 200V relay sequence circuit).
When using a blade terminal (without insulation sleeve), take caution that the twisted wires do not come out.
FR Series Manual Controller/Speed controller
Manual controller FR-AX
For independent operation. With frequency meter, frequency
setting potentiometer and start switch.
Applicable for all
models
DC tach. follower FR-AL
For synchronous operation (1VA) by external signal (0 to 5V,
0 to 10V DC) *
Three speed selector FR-AT
For three speed switching among high, middle and low
speed operation (1.5VA)*
Motorized speed setter FR-FK
For remote operation. Allows operation to be controlled from
several places (5VA)*
Ratio setter FR-FH
For ratio operation. Allows ratios to be set to five inverters.
(3VA)*
Speed follower FR-FP
For tracking operation by a pilot generator (PG) signal
(3VA)*
Master controller FR-FG
Master controller (5VA) for parallel operation of multiple
(maximum 35) inverters.*
Soft starter FR-FC
For soft start and stop. Enables acceleration/deceleration in
parallel operation (3VA)*
Deviation detector FR-FD
For continuous speed control operation. Used in
combination with a deviation sensor or synchro (5VA)*
Preamplifier FR-FA Used as an A/V converter or arithmetic amplifier (3VA)*
Others
Pilot generator QVAH-10 For tracking operation. 70V/35VAC 500Hz (at 2500r/min)
Deviation sensor
YVGC-500W-
NS
For continuous speed control operation (mechanical
deviation detection). Output 90VAC/90°
Frequency setting
potentiometer
WA2W 1kΩ For frequency setting. Wirewound 2W 1k B characteristic
Frequency meter
(64mm × 60mm)
YM206NRI
1mA
Dedicated frequency meter (graduated to 120Hz). Moving-
coil type DC ammeter
Calibration resistor RV24YN 10kΩ
For frequency meter calibration. Carbon film type B
characteristic
FR Configurator SW3
(Inverter setup software)
FR-SW3-
SETUP-W
Supports an inverter startup to maintenance.
FR-SW1-SETUP-W is also available for installation.
Applicable for all
models
Name Model Manufacturer Applications, Specifications, etc.
Communication connector 5-554720-3 Tyco Electronics RJ-45 connector
Communication cable
SGLPEV-T
(Cat5e/300m)
24AWG × 4
Mitsubishi Cable
Industries, Ltd.
Cat.5e cable that is compatible with TIA/EIA standards.
(10BASE-T/100BASE-T/1000BASE-T)
Name Model Applications, Specifications, etc.
Applicable
Inverter
Terminal
Screw Size
Wire Size
(mm
2
)
Blade Terminal Model
Blade Terminal
Crimping Tool
(with insulation
sleeve)
(without
insulation sleeve)
M2 0.3, 0.5 AI 0,5-6WH A 0,5-6 CRIMPFOX 6
Terminal
Screw Size
Wire Size
(mm
2
)
Blade Terminal
Product Number
Insulation Product
Number
Blade Terminal
Crimping Tool
M2 0.3 to 0.75 BT 0.75-7 VC 0.75 NH 67