Mitsubishi Electronics FR-F720P Marine Battery User Manual


 
368
*1 These instruction codes are used for parameter read and write by using Mitsubishi inverter protocol with the RS-485 communication.
(Refer to page 229 for RS-485 communication)
*2 Validity and invalidity according to operation mode are as follows:
:Usable parameter
×:Unusable parameter
*3 "" indicates valid and "
×" indicates invalid of "parameter copy", "parameter clear", and "all parameter clear".
*4 These parameters are communication parameters that are not cleared when parameter clear (all clear) is executed from RS-485 communication.
(Refer to page 229 for RS-485 communication)
*5 When a communication option is installed, parameter clear (lock release) during password lock (Pr. 297 9999) can be performed only from the
communication option.
Symbols in the table indicate parameters which function when an option is mounted.
.......FR-A7AX, ....... FR-A7AY, ........ FR-A7AR, ........FR-A7NC, ....... FR-A7ND,
.......FR-A7NL, ....... FR-A7NP, ........ FR-A7NF
Appendix 3 Parameter clear, parameter copy and instruction code list
Parameter
Name
Instruction Code *1
Control Mode-based
Correspondence Table
*2
Parameter
Copy
*3
Parameter
Clear
*3
All
Parameter
Clear
*3
Read Write
Extended
V/F
control
Simple
magnetic
flux vector
control
IPM motor
control
0
Torque boost
00 80 0
××

1
Maximum frequency
01 81 0
2
Minimum frequency
02 82 0

3
Base frequency
03 83 0
×
4
Multi-speed setting (high
speed)
04 84 0

5
Multi-speed setting (middle
speed)
05 85 0
6
Multi-speed setting (low
speed)
06 86 0

7
Acceleration time
07 87 0
8
Deceleration time
08 88 0

9
Electronic thermal O/L relay
09 89 0
10
DC injection brake operation
frequency
0A 8A 0

11
DC injection brake operation
time
0B 8B 0
12
DC injection brake operation
voltage
0C 8C 0

×

13
Starting frequency
0D 8D 0
14
Load pattern selection
0E 8E 0
××

15
Jog frequency
0F 8F 0
16
Jog acceleration/deceleration
time
10 90 0

17
MRS input selection
11 91 0
18
High speed maximum
frequency
12 92 0

19
Base frequency voltage
13 93 0
×
20
Acceleration/deceleration
reference frequency
14 94 0

21
Acceleration/deceleration time
increments
15 95 0
22
Stall prevention operation level
(Torque limit level )
16 96 0

23
Stall prevention operation
level compensation factor at
double speed
17 97 0
×
24
Multi-speed setting (speed 4)
18 98 0

25
Multi-speed setting (speed 5)
19 99 0
26 Multi-speed setting (speed 6)
1A 9A 0

27 Multi-speed setting (speed 7)
1B 9B 0
V/F
V/F
V/F
S
MFVC
S
MFVC
S
MFVC
IPM
IPM
IPM