Mitsubishi Electronics FR-F720P Marine Battery User Manual


 
365
For customers who are replacing the conventional model with this inverter
(4) Main differences and compatibilities with the FR-F500(L) series
Appendix 1-2 Replacement of the FR-A100 <EXCELENT> series
Instructions for installation
When using the installation holes of the FR-A100(E) series, FR-A5AT (intercompatibility attachment) is necessary.
Item FR-F500(L) FR-F700P
Changed
function
Simple mode
parameter
61 parameters 17 parameters
User group
User group 1 (16 parameters), User group 2 (16
parameters) (Pr.160, Pr.173 to Pr.175)
User group (16 parameters) only
Setting methods were partially changed
(Pr.160, Pr.172 to Pr.173)
Communication
option
Performing the parameter clear or all parameter clear
(H5A96 or HAA99) from the DeviceNet
communication option (FR-A5ND) clears the Pr. 345
and Pr. 346 settings.
Performing the parameter clear or all parameter clear
(H5A96 or HAA99) from the DeviceNet
communication option (FR-A7ND) does not clear the
Pr. 345 and Pr. 346 settings.
Changed
initial value
Pr.0
Torque boost
2% for 11K to 55K
2% for 11K to 37K, 1.5% for 45K and 55K
(If the torque boost setting was being used in the
initial setting in the FR-F500 series, the setting does
not need to be changed from the initial setting after
the inverter is replaced with the FR-F700P series. )
Deleted
function
User initial
value setting
(Pr.199)
Available
Not available
Substitutable with the copy function of the operation
panel (FR-DU07)
DC injunction
function with
terminal
With a terminal (X13 signal)
(Setting value "8888" for Pr.11, setting value "13" for
Pr.180 to Pr.186)
Not available
Start in the reverse rotation is possible with the flying
start function (frequency search of the automatic
restart after instantaneous power failure function)
Long wire mode Setting values "10 and 11" for Pr.240
Setting is not necessary
(Setting values "10 and 11" for Pr.240 are deleted.)
Intelligent
optimum
acceleration/
deceleration
Available
(Pr.60 setting "3" and Pr.61 to Pr.63)
Not available
For deceleration time, overvoltage fault can be
avoided with the regeneration avoidance function
(Pr.882 to Pr.885).
Automatic
torque boost
Pr.38, Pr.39
The automatic torque boost is deleted because the
Simple magnetic flux vector (Pr.80) has been added.
Terminal block Removable terminal block
Removable terminal block
Upward compatibility (Terminal block of the F500 can
be mounted)
PU FR-PU04, DU04
FR-PU07
FR-DU07
FR-DU04 unavailable (Partly restricted when the FR-
PU04 is used. Refer to page 364.)
Plug-in option
Dedicated plug-in option (not compatible)
Computer link, relay output option
FR-A5NR
Built into the inverter
(RS-485 terminal, relay output 2 points)
Three boards can be mounted One board can be mounted
Installation size
FR-F720P-0.75K, 2.2K, 3.7K, 7.5K, 18.5K, 22K, 37K, 45K,
FR-F740P-0.75K to 3.7K, 7.5K, 11K, 22K, 37K to 55K are compatible in mounting dimensions
For other capacities, an optional intercompatibility attachment (FR-AAT) is necessary.