Troubleshooting the System
Page 8-13Single-Line Phones Ring Back after Completed Call
8
assigned for that group has Night Service turned on; other QCCs need not have
Night Service turned on.
If the green light is on at all QCCs in the system, then Night Service is
turned on. Press the button to deactivate the feature and to turn the light
off. Finally, check to see whether incoming calls ring at the console. If they
do, you have solved the problem. If not, go to Possible Cause 5.
If the green light is off, then Night Service is not turned on; go to Possible
Cause 5.
Possible Cause 5:
The telephone may be defective.
What to do: Test the telephone by replacing it with another MLX-20L telephone
that you know is working properly.
If only one MLX-20L is available, plug that telephone into a jack that you
know is working and then retest. If the telephone rings for incoming calls,
then the original jack may be faulty; call the Lucent Technologies Helpline
at 1 800 628-2888 (consultation charges may apply). If the telephone still
does not ring, there may be a problem with the system wiring or the control
unit; call the Lucent Technologies Helpline at 1 800 628-2888.
If the replacement telephone rings for incoming calls, then replace it with
the original telephone and check again. If the original telephone still does
not ring for incoming calls, then the original telephone may be defective.
Call the Lucent Technologies Helpline at 1 800 628-2888 (consultation
charges may apply).
If the replacement telephone does not ring for incoming calls, there may be
a problem with the system wiring or the control unit. Call the Lucent
Technologies Helpline at 1 800 628-2888 (consultation charges may
apply).
Single-Line Phones Ring Back after
Completed Call 8
Possible Cause 1:
The switchhook is pressed and released too quickly after a
call is completed.
NOTE:
Some single-line telephones have a positive disconnect switch. If the
switch is set to positive disconnect, Possible Cause 1 does not apply. In
this case, skip to Possible Cause 2.