Parameter Unit (FR-PU04) Setting
3.8.3 PU contrast adjustment (Pr. 991)
3.8.4 PU main display screen data selection (Pr. 992)
When you set 100 in Pr. 992, the monitor value changes depending on whether the
inverter is at a stop or running.
You can adjust the LCD contrast of the parameter unit (FR-PU04). When using the
FR-PU04, adjust the numerical value to any depth of a color with the / keys
and define that color with the key of the parameter unit.
CAUTION
When using the FR-PU04, you should press the key to store the LCD
contrast setting.
You can choose the main display screen of the parameter unit (FR-PU04).
Pr.992
0
(Factory setting)
100
During operation/stop During stop During operation
Output frequency Output frequency Set frequency Output frequency
Output current Output current
Alarm display Alarm display
REMARKS
•During an error, the output frequency at error occurrence appears.
•During MRS, the values displayed are the same as during a stop.
WRITE
Paramet
er
Name
Factory
Setting
Setting
Range
991
PU contrast
adjustment
58 0 to 63
0 (Pale)
63 (Deep)
WRITE