52
Function (Parameter) List
Parameter List
Operation selection
77*
Parameter write
disable selection
0: Write enabled only
during stop
1: Write disabled
(except some)
2: Write enabled
during operation
1074
79
Operation mode
selection
0: PU/external
switchable
1: PU 2: External
3: External/PU
combined
4: External/PU
combined
1075
FR-PU04
145
PU display
language
selection
0: Japanese
1: English
2: German
3: French
4: Spanish
5: Italian
6: Swedish
7: Finish
1093
Computer link
331
RS-485
communication
station number
setting
0 to 31: Specify the
station
number of the
inverter.
1079
332
RS-485
communication speed
48:4800bps,
96:9600bps
192:19200bps
19679
333 Stop bit length
0: Data length 8,
stop bit 1
1: Data length 8,
stop bit 2
10: Data length 7,
stop bit 1
11: Data length 7,
stop bit 2
1079
334
Parity check
presence/absence
0: Absence
1: With odd parity
check
2: With even parity
check
1179
335
Number of
communication retries
0 to 10, 9999 1 1 79
336
Communication check
time interval
0 to 999s, 9999 0.1s 9999 79
337 Waiting time setting 0 to 150ms, 9999 1 9999 79
Func
tion
Para-
meter
Name Setting Range
Minimum
Setting
Increme
nts
Factory
Setting
Refer
ence
Page
Custo
mer
Setting
•
indicates the communication parameters. Note them when clearing the parameters.
(Refer to pages 89, 125.)