69
I/O Terminal Function Selection
3
INVERTER FUNCTIONS
3.5.2 Output terminal function selection (Pr. 64, Pr. 505)
<Setting>
You can change the functions of the open collector and contact output terminals.
Param
eter
Name
Factory
Setting
Setting
Range
64 RUN terminal function selection 0
0, 3, 99, 9998
506 ALM terminal function selection 99
Setting
Signal
Name
Function Operation
Referen
ce Page
0 RUN Inverter running
Output during operation when the inverter output
frequency rises to or above the starting frequency.
58, 62
3 OL Overload alarm Output while stall prevention function is activated. 63
99 ALM Alarm output
Output when the inverter's protective function is
activated to stop the output (major fault).
9998 No function
No function (Can be used as a general-purpose
input terminal using the PLC function.)
REMARKS
The same function may be set to more than one terminal.