Errors (Alarms)
PROTECTIVE FUNCTIONS
6
6.1.2 To know the operating status at the occurrence of alarm
(Only when FR-PU04 is used)
When any alarm has occurred, the display automatically switches to the indication of
the corresponding protective function (error). By pressing the key at this point
without resetting the inverter, the display shows the output frequency. In this way, it is
possible to know the running frequency at the occurrence of the alarm. It is also
possible to know the current in the same manner.
After resetting, you can confirm the definitions in "Alarm History". (For details, refer to
the instruction manual of the parameter unit (FR-PU04).)
6.1.3 Correspondences between digital and actual characters
There are the following correspondences between the actual alphanumeric characters
and the digital characters displayed on the operation panel:
6.1.4 Resetting the inverter
The inverter can be reset by performing any of the following operations. Note that the
electronic overcurrent protection's internal heat calculation value and the number of
retries are cleared (erased) by resetting the inverter.
It takes about 1s to reset the inverter.
Operation 1....... Using the operation panel, press the key to reset the inverter.
(Enabled only when the inverter protective function (major failure) is
activated.)
Operation 2....... Switch power off once, then switch it on again.
Operation 3....... Turn on the reset signal (RES). (Assign this signal to any of Pr. 60 to
Pr. 63, Pr. 65 and Pr. 505.) (Refer to page 20, 68.)