Debugging Mode Specifications
4.10 Debugging Mode Specifications
You can forcibly turn on/off the external I/O terminals and CC-Link remote inputs/
outputs.
For inputs, the input signals from the outside or CC-Link to the inverter are ignored.
For outputs, the output signals from the inverter to the outside or CC-Link are ignored.
* The parameter values set using the FR-PU04 are all decimal numbers.
* When the control input terminals are turned on forcibly, they are enabled in the external/CC-
Link operation mode.
<Setting method>
Make setting after converting a bit string (binary) into decimal.
<Example>
When turning on control input terminals STF, RM forcibly
Bit (binary) 00001001 9 (decimal)
Set "3" in Pr. 530 and "9" in Pr. 531.
Inverter
Parameter
Name
Factory
Setting
Setting
Range
Minimum
Setting Unit
Remarks
530
Forced I/O
selection
9999 1,2,3,4,9999 1
1: CC-Link remote inputs
2: CC-Link remote outputs
3: Control input terminals
4: Control output terminals
9999: Function disable
531
Forced I/O
setting L
9999 0 to 255,9999 1 9999: Forced output off
532
Forced I/O
setting H
9999 0 to 255,9999 1 9999: Forced output off
Pr.530
Corresponding
Pr.
Details (Bit String)
1
Pr.531
Pr.532
2
Pr.531
Pr.532
3Pr.531
4Pr.531
POINT
To return to function disable, set "9999" in Pr. 530.
If "9999" is not set in Pr. 530, the debugging mode signal is enabled and the
control I/O terminal signals are disabled, affecting operation. Note this when
using the parameter.
RX7 RX6 RX5 RX4 RX3 RX2 RX1 RX0
7
0
CC-Link
remote inputs L
to
70
RXF RXE RXD RXC RXB RXA RX9 RX8
to
C
C-Link
r
emote inputs H
7
0
RY7 RY6 RY5 RY4 RY3 RY2 RY1 RY0
to
C-Link
emote outputs L
70
RYF RYE RYD RYC RYB RYA
RY9
RY8
to
C-Link
emote outputs H
70
-
-
SQ RH RM RL STR STF
to
Control
input terminals
70
-
ALM RUN
to
C
ontrol
o
utput terminals
-----