Inputs/Outputs
4
PLC FUNCTION
External: External input terminal valid.
Internal memory: External input terminal invalid. Used as contact.
CC-Link: CC-Link terminal function valid.
Internal memory: CC-Link terminal function disable. Acts as user-set input signal in
(CC-Link) CC-Link communication.
Input terminal function selection (Pr. 60 to Pr. 63, Pr. 65, Pr. 505) enables function
selection.
In the factory setting, the relationships between the parameter numbers and terminals
are as indicated in the following table.
X20 to X2F are used as completion signals for read/write of data from/to the special
registers, parameters and user parameters. (They cannot be used freely by the user.)
For details, refer to pages 117 to 135.
CC-Link
operation
X13 RM CC-Link CC-Link CC-Link
Internal
memory
(CC-Link)
X14 RH CC-Link CC-Link CC-Link
Internal
memory
(CC-Link)
X15 SQ CC-Link CC-Link CC-Link CC-Link
X16 to
X1F
Empty
Internal
memory
(CC-Link)
Internal
memory
(CC-Link)
Internal
memory
(CC-Link)
Internal
memory
(CC-Link)
Parameter Name External Terminal CC-Link
60 RL terminal X02 X12
61 RM terminal X03 X13
62 RH terminal X04 X14
63 STR terminal X01 X11
65 STF terminal X00 X10
505 SQ terminal X05 X15
$
$$
$Related parameters$
$$
$
Input terminal function selection Pr. 60 to Pr. 63, Pr. 65, Pr. 505 (Refer to page 68.)
Operation command source, speed command source Pr. 338, Pr. 339 (Refer to page 75.)
REMARKS
Operation commands can also be set using the special registers D9148, D9149. (Refer to
page 126.)
Mode
Terminal
Pr. 338 "operation
command source"
Pr. 339 "speed command
source"
No. Name 0:CC-Link 1: External 0:CC-Link 1: External