Mitsubishi Electronics FR-HC2 Marine Battery User Manual


 
100
Description of parameters
Data reading format
Communication request data from the computer to the converter 1)
Reply data from the converter to the computer 3) (No data error detected)
Reply data from the converter to the computer 3) (With data error)
Send data from the computer to the converter 5)
Format
Number of Characters
1 2 3 4 5 6 7 8 9
B
ENQ

Station number  Instruction code

Sum
check

Format
Number of Characters
1 2 3 4 5 6 7 8 9 10 11
E
STX

Station number  Read data
ETX

Sum
check

E1
STX

Station number  Read data
ETX

Sum
check

Format
Number of Characters
1 2 3 4 5
D
NAK

Station number 
Error
code

Format
Number of Characters
1 2 3 4
C
(Without
data error)
ACK

Station number 

F
(With data
error)
NAK

Station number 

 Indicate a control code
 Specify the station numbers between H00 and H1F (stations 0 to 31) in hexadecimal.
 Waiting time
When Pr.123 (Waiting time setting) 9999, create a communication request data without "waiting time" in the data format. (The number of
characters decreases by 1.)
 CR, LF code
When data is transmitted from the computer to the converter, codes CR (carriage return) and LF (line feed) are automatically set at the end of
a data group on some computers. In this case, setting must also be made on the converter according to the computer. Whether the CR and LF
codes will be present or absent can be selected using Pr. 124 (CR/LF selection).
HC2.book 100 ページ 2012年11月19日 月曜日 午前10時52分