Mitsubishi Electronics FR-HC2 Marine Battery User Manual


 
108
Description of parameters
[Special monitor selection No.]
Refer to page 86 for details of the monitor description.
 Differ according to capacities. (55K or lower/75K or higher)
 The regenerative status cannot be displayed. The regenerative status display is available only on the operation panel (FR-DU07-CNV).
 Input terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, : undetermined value)
 Output terminal monitor details (when the terminal is ON: 1, when the terminal is OFF: 0, : undetermined value)
[Fault data]
Refer to page 126 for details of fault description.
[Converter status monitor]
The signal within parentheses is in the initial status. Definitions change according to the Pr. 11 to Pr. 16 (output terminal function selection).
b15 b0
RES SOF ROH X2 X1 
b15 b0
88R ABC Y3 Y2 Y1 CVO RSO RDY
Item
Instruction
Code
Bit
Length
Description Example
Converter
status
monitor
H7A 8 bits
b0 : RDY(Inverter run permission)
b1 : Power driving
b2 : Regenerative driving
b3 : RSO (converter reset)
b4 : Y1 (overload)
b5 : Y2 (power supply phase
detecting)
b6 : CVO (converter running)
b7 : 88R (input contactor control)
Converter
status
monitor
(expansion)
H79 16 bits
b0 : RDY (Inverter run permission)
b1 : Power driving
b2 : Regenerative driving
b3 : RSO (converter reset)
b4 : Y1 (overload)
b5 : Y2 (power supply phase
detecting)
b6 : CVO (converter running)
b7 : 88R (input contactor control)
b8 : ABC (fault)
b9 :
b10 :
b11 :
b12 :
b13 :
b14 :
b15 : Fault occurrence
Data Description Increments
H01 Input current 0.01A/0.1A
H02 Input voltage 0.1V
H03 Bus voltage 0.1V
H05 Power supply frequency 0.01Hz
H06
Electronic thermal relay
load factor
0.1%
H07 Input power
0.01kW/
0.1kW

H08 Cumulative power 1kWh
H09
Cumulative
energization time
1h
Data Description Increments
H0A Input power*2
0.1kW/
1kW

H0F Input terminal status 
H10 Output terminal status

Data Description Increments
For read data H30B1
(Previous fault ...... THT)
(Latest fault ...... OPT)
0
1
0
1
0000 0 1 1000
11
b15 b8b7 b0
Latest fault
(HB1)
Previous fault
(H30)
Fault record display example (instruction code H74)
Data Description
H00
No fault
present
H11 E.OC2
H21 E.OV2
H30 E.THT
H40 E.FIN
H50 E.IPF
H51 E.UVT
H52 E.ILF
H90 E.OHT
HA3 E.OP3
HB0 E.PE
HB1 E.PUE
HB2 E.RET
HB3 E.PE2
HC0 E.CPU
HC1 E.CTE
HC2 E.P24
HC4 E.CDO
HC5 E.IOH
HF2 E.2
HF3 E.3
Data Description
HF6 E.6
HF7 E.7
HF8 E.8
HF9 E.9
HFD E.13
Data Description
00000010
b7 b0
[Example 1] HO2: Power driving
[Example 2] H40: Converter running
01000000
b7 b0
00000010
b0
00000000
b15
[Example 1] HO2: Power driving
00000000
b0
10000001
b15
H8100: Trip by a fault
HC2.book 108 ページ 2012年11月19日 月曜日 午前10時52分