Mitsubishi Electronics FR-HC2 Marine Battery User Manual


 
105
3
PARAMETERS
Description of parameters
General flowchart
Port open
Communication setting
Time out setting
Send data processing
Data setting
Sum code calculation
Data transmission
Receive data waiting
Receive data processing
Data retrieval
Screen display
CAUTION
Always set the communication check time interval before starting operation to prevent hazardous conditions.
Data communication is not started automatically but is made only once when the computer provides a communication
request. If communication is disabled during operation due to signal loss etc., the converter (inverter) cannot be
stopped. Turn the RES signal ON or shut off the power supply to coast the motor to a stop and to stop the converter
(inverter) operation.
If communication is broken due to signal cable breakage, computer fault etc., the converter does not detect such a
fault. This should be fully noted.