INSTALLATION AND WIRING
Wiring of main circuit (FR-HC2-H280K)
2.8 Wiring of main circuit (FR-HC2-H280K)
Perform wiring securely to conform with the harmonic suppression guideline of the former Ministry of International
Trade and Industry (currently the Japanese Ministry of Economy, Trade and Industry). Incorrect wiring causes the
converter to display an alarm or causes an fault or damage.
Refer to the Instruction Manual of each inverter for the wiring of the inverter. Special attention must be paid to the wiring
length and wire gauge.
2.8.1 Connection diagram (when using with the FR-A700 series)
Connection method differs by the inverter series. Perform connection by referring to the Instruction Manual of the inverter.
Do not connect anything to the inverter power input terminals R/L1, S/L2 and T/L3. Incorrect connection will damage the inverter. Connecting opposite
polarity of terminals P/+ and N/- will damage the converter and the inverter.
Use input terminal function selection to assign the terminal used for X10 signal. (Refer to the Instruction Manual of the inverter.)
The power phases of the terminals R4/L14, S4/L24, and T4/L34 and the terminals R/L1, S/L2, and T/L3 must be matched.
Do not insert MCCB between terminals P/+ and N/- (P and P, N and N).
Always connect the terminal R/L1, S/L2, T/L3 of the converter to the power supply. If the inverter is operated without connecting the terminals to the power
supply, the converter will be damaged.
Do not insert MCCB or MC between (1) (terminal R/L1, S/L2, and T/L3 input of the Reactor 1) and (3) (terminal R4/L14, S4/L24, and T4/L34 input of the
converter) of the above diagram. It will not operate properly (except for the inrush current limit MC).
Securely perform grounding (earthing) by using the grounding (earthing) terminal.
Installation of a fuse is recommended. (Refer to page 13)
Number Wiring Refer to page
(1) Power supply and reactor 1 43
(2) Reactor 1 and reactor 2 43
(3) Reactor 2 and converter 44
(4) Converter and inverter 45
(5) Reactor 1 and converter 45
(6) Power supply and inverter 46
Inverter
Converter
(FR-HC2)
Filter capacitors
(FR-HCC2)
Limit
resistors
Motor
Reactor 1
(FR-HCL21)
Power
Supply
MCCB
Limit
MC
Buffer relay for
driving MC
MC power
supply stepdown
transformer
Reactor 2
(FR-HCL22)
Auxiliary contact for
limit MCs (NO contact)
Limit resistor
(with a thermostat) (NC contact)
MC
Converter stop
Monitor
switching
Converter reset
Contact input common
Monitor
switching
Inverter run
enable signal
Converter
reset
During
converter
run
Multi-purpose
output 1
Open collector
output common
Multi-purpose
output 2
(-)
(+)
Analog signal output
(0 to 10VDC)
PU
connector
Relay
output
(Fault
output)
MC connection terminal
MC connection terminal
Inrush current
limit resistor
overheat
protection
Contact
input
common
24VDC power supply
(External transistor
common)
Earth
(Ground)
MC
P/+
P/+
N/-
N/-
R1/L11
S1/L21
X10
RES
SD
RDY
RSO
CVO
Y1
Y2
SE
R4/L14
R/L1
S/L2
T/L3
S4/L24
T4/L34
R4/
L14
S4/
L24
T4/
L34
R3/
L13
S3/
L23
T3/
L33
R2/
L12
S2/
L22
T2/
L32
R/
L1
S/
L2
T/
L3
U
V
W
88R
R/L1
S/L2
T/L3
88S
R1/L11
S1/L21
MC
Bu1
MC
ROH
SD
Y3
SE2
FM
SD
Indicator
+
-
A
B
C
AM
5
SOF
X1
X2
RES
SD
PC
Fuses
Open collector
output common
Multi - purpose output 3
(1)
(2)
(3)
(4)
(5)
(6)
HC2.book 41 ページ 2012年11月19日 月曜日 午前10時52分