Section 4: Starting up
February 2015
Figure 4-1. Display and push-buttons
4.1.2 Power up
When the power is turned on, the transmitter takes several seconds to initialize. The display will
run a set-up routine, first illuminating all display characters, and then showing the software
revision number. Finally, a full set of zeros is displayed while the microprocessor identifies the
correct return echo. After these checks are complete, the display indicates the live
measurement based upon the factory default values in memory.
On a new instrument aimed at a good target, the transmitter calculates a level reading based
upon the default value for the bottom reference.
The duty icon against the letter L on the top plate, and the RL2 icon on The MSP400RH, will be
illuminated. The RL1 icon on the MSP400RH may be illuminated, depending on the level
calculated by the transmitter at this time.
The transmitter is now ready to be set-up with details of the application.
The transmitter may be programmed prior to, or after, installation. All programmed data is
retained in the transmitter memory after the power is turned off.
Green
Button
Red
Button
Alarm
Fault
Blue
Button
D
L
F
C