65
Reference Manual
IP2048/RM, Rev AA
Appendix A: Reference Data
February 2015
Output cabling
Single twisted-pair and shielded,
min. 0,22 mm
2
(24 AWG),
max. 1,5 mm
2
(15 AWG)
A.1.5 Physical specifications
Materials selection
Emerson provides a variety of product with various product options and configurations
including materials of construction that can be expected to perform well in a wide range of
applications. The product information presented is intended as a guide for the purchaser to
make an appropriate selection for the application. It is the purchaser’s sole responsibility to
make a careful analysis of all process parameters (such as all chemical components,
temperature, pressure, flow rate, abrasives, contaminants, etc.), when specifying product,
materials, options and components for the particular application. Emerson Process
Management is not in a position to evaluate or guarantee the compatibility of the process
fluid or other process parameters with the product, options, configuration or materials of
construction selected.
Materials used in construction
Wet-side material: PVDF
Body and cover material: Glass-filled nylon
Cover seal: Silicone rubber
Cover screws: 316 Stainless Steel
Transducer body seal: EPDM
A.1.6 Mechanical
Mounting thread size
2-in. NPT, or 2-in. BSP. Optional flange accessories available
Weight of transmitter
MSP400RH: 2.2 lb (1,0 kg)
MSP900GH: 3.1 lb (1,4 kg)
A.1.7 Measuring
Temperature compensation
(1)
Automatic Integral temperature compensation.
(Optional remote temperature sensor for dynamic temperature compensation)
(1) See Product Data Sheet for optional accessories.