Hitachi SJ700-2 Marine Battery User Manual


 
Chapter 8 List of Data Settings
8 - 11
Default
Code Function name Monitored data or setting
_FF _FEF _FUF
Setting
during
operation
(allowed
or not)
Change
during
operation
(allowed
or not)
Page
C038
Low-current indication signal
output mode selection
00 (output during acceleration/deceleration and constant-speed operation),
01 (output only during constant-speed operation)
01
¯ {
C039
Low-current indication signal
detection level
0.0 to 2.00 x "rated current" (A) Rated current of inverter
{ {
4-69
C040 Overload signal output mode
00 (output during acceleration/deceleration and constant-speed operation),
01 (output only during constant-speed operation)
01
¯ {
C041 Overload level setting 0.0 to 2.00 x "rated current" (A) Rated current of inverter
{ {
4-40
C042 Frequency arrival setting for accel. 0.00 to 99.99, 100.0 to 400.0 (Hz) 0.00
¯ {
C043 Frequency arrival setting for decel. 0.00 to 99.99, 100.0 to 400.0 (Hz) 0.00
¯ {
4-62
C044 PID deviation level setting 0.0 to 100.0 (%) 3.0
¯ {
4-29
C045
Frequency arrival setting for
acceleration (2)
0.00 to 99.99, 100.0 to 400.0 (Hz) 0.00
¯ {
C046
Frequency arrival setting for
deceleration (2)
0.00 to 99.99, 100.0 to 400.0 (Hz) 0.00
¯ {
4-62
C052 Maximum PID feedback data 0.0 to 100.0 (%) 100.0
¯ {
C053 Minimum PID feedback data 0.0 to 100.0 (%) 0.0
¯ {
4-29
C055
Over-torque (forward-driving) level
setting
0. to 200. (%) 100.
¯ {
C056
Over-torque (reverse
regenerating) level setting
0. to 200. (%) 100.
¯ {
C057
Over-torque (reverse driving) level
setting
0. to 200. (%) 100.
¯ {
C058
Over-torque (forward
regenerating) level setting
0. to 200. (%) 100.
¯ {
4-65
C061
Electronic thermal warning level
setting
0. to 100. (%) 80.
¯ {
4-38
C062 Alarm code output 00 (disabling), 01 (3 bits), 02 (4 bits) 00
¯ {
4-65
C063 Zero speed detection level 0.00 to 99.99, 100.0 (Hz) 0.00
¯ {
4-64
Levels and output terminal status
C064 Heat sink overheat warning level
0. to 200.0 (°C)
120.
¯ {
4-68
C071 Communication speed selection
02 (loopback test), 03 (2,400 bps), 04 (4,800 bps), 05 (9,600 bps), 06
(19,200 bps)
04
¯ {
C072 Node allocation 1. to 32. 1.
¯ {
C073
Communication data length
selection
7 (7 bits), 8 (8 bits) 7
¯ {
C074 Communication parity selection 00 (no parity), 01 (even parity), 02 (odd parity) 00
¯ {
C075 Communication stop bit selection 1 (1 bit), 2 (2 bits) 1
¯ {
C076
Selection of the operation after
communication error
00 (tripping), 01 (tripping after decelerating and stopping the motor), 02
(ignoring errors), 03 (stopping the motor after free-running), 04
(decelerating and stopping the motor)
02
¯ {
C077
Communication timeout limit
before tripping
0.00 to 99.99 (s) 0.00
¯ {
C078 Communication wait time 0. to 1000. (ms) 0.
¯ {
Communication function
C079 Communication mode selection 00(ASCII), 01(Modbus-RTU) 00
¯ {
4-113
C081 [O] input span calibration 0. to 9999., 1000 to 6553(10000 to 65530) Factory setting
{ {
C082 [OI] input span calibration 0. to 9999., 1000 to 6553(10000 to 65530) Factory setting
{ {
C083 [O2] input span calibration 0. to 9999., 1000 to 6553(10000 to 65530) Factory setting
{ {
C085 Thermistor input tuning 0.0 to 999.9, 1000. Factory setting
{ {
4-72
Adjustment
C091 Debug mode enable (Do not change this parameter, which is intended for factory adjustment.) 00
¯ ¯
C101 Up/Down memory mode selection 00 (not storing the frequency data), 01 (storing the frequency data) 00
¯ {
4-56
C102 Reset mode selection
00 (resetting the trip when RS is on), 01 (resetting the trip when RS is off), 2
(enabling resetting only upon tripping [resetting when RS is on])
00
{ {
Others
C103 Restart mode after reset
00 (starting with 0 Hz), 01 (starting with matching frequency), 02 (restarting
with active matching frequency)
00
¯ {
4-54
C105 FM gain adjustment 50. to 200. (%) 100.
{ {
4-73
C106 AM gain adjustment 50. to 200. (%) 100.
{ {
C107 AMI gain adjustment 50. to 200. (%) 100.
{ {
C109 AM bias adjustment 0. to 100. (%) 0.
{ {
Meter
adjustment
C110 AMI bias adjustment 0. to 100. (%) 20.
{ {
4-74