Hitachi SJ700-2 Marine Battery User Manual


 
Appendix
A - 2
(2) Copying the parameter settings
If you use an optional remote operator (SRW-OJ or SRW-OEX), you can copy (import) the parameter
settings from the SJ300 series into the SJ700 series. Note, however, that you cannot copy the
parameter settings from the SJ700 series to the SJ300 series because the SJ700 series has many
new functions and additional parameters.
Precaution: Copying of the data on an optional operator (SRW or SRW-EX)
If you copy parameter data from the SJ700 or SJ300 series inverter in which the slide switch SW1 is
set to OFF to the SJ700 series inverter in which the slide switch SW1 is set to ON, the operator may
momentarily display an error message "R-ERROR COPY ROM." This event occurs because the data
on intelligent input terminals [1] and [3] cannot be copied because the copy-destination SJ700 series
has exclusively assigned special functions to these terminals according to the ON setting of the slide
switch SW1. Other parameter data is copied. In such cases, confirm the parameter settings on both
copy-source and copy-destination inverters before using the copy-destination SJ700 series.
After copying the data, be sure to power off and on again to reflect the copied data.
(3) Option boards
You can use the option boards (SJ-FB, SJ-DG, SJ-DN, SJ-LN, and SJ-PB) mounted in the SJ300
series for the SJ700 series.
To mount the option boards in the SJ700 series, follow the same mounting procedure as that used for
the SJ300 series. For details, refer to the instruction manual for each option board.
Precaution: Since the SJ700 series has many new functions and additional parameters, some
functions of the SJ-DN, SJ-LN, and SJ-PB (option boards conforming to the open network
specifications) cannot be implemented on the SJ700 series.