Emerson Process Management 5300 Marine RADAR User Manual


 
Reference Manual
00809-0100-4530, Rev BA
July 2009
Rosemount 5300 Series
7-36
Errors Error messages that may be displayed on the Integral Display, on a 375
Handheld Communicator, in AMS, or in RRM are shown in Table 7-5. Errors
normally result in Analog Output alarm.
Errors are indicated in RRM in the Diagnostics window.
Table 7-5. Error messages.
Message Description Action
RAM error An error in the gauge data memory
(RAM) has been detected during the
startup tests. Note: this automatically
resets the gauge.
Contact Emerson Process
Management Service Department.
FPROM error An error in the gauge program
memory (FPROM) has been detected
during the startup tests. Note: this
automatically resets the gauge.
Contact Emerson Process
Management Service Department.
Database (Hreg) error An error in the transmitter
configuration memory (EEPROM) has
been detected. The error is either a
checksum error that can be solved by
loading the default database or a
hardware error.
NOTE: the default values are used
until the problem is solved.
Load default database and restart the
transmitter. Contact Emerson
Process Management Service
Department if the problem persists.
Microwave Module error An error in the microwave module. Contact Emerson Process
Management Service Department.
LCD error An error in the LCD is detected. Contact Emerson Process
Management Service Department.
Modem error An error in the modem used for digital
communication has been detected.
Contact Emerson Process
Management Service Department.
Analog out error An error in the Analog Out Module. Contact Emerson Process
Management Service Department.
Internal temperature error An error in the internal temperature
measurement.
-40 ºC<Internal Temperature<85 ºC.
Contact Emerson Process
Management Service Department.
Other hardware error An unspecified hardware error has
been detected.
Contact Emerson Process
Management Service Department.
Measurement error A serious measurement error has
been detected.
Contact Emerson Process
Management Service Department.
Configuration error At least one configuration parameter
is outside allowed range.
NOTE: the default values are used
until the problem is solved.
Load the default database and
restart the transmitter (see “Reset
to Factory Settings” on page 7-22)
Configure the transmitter or upload
a backup configuration file (see
“Backing up the Transmitter
Configuration” on page 7-20)
Contact Emerson Process
Management Service Department if
the problem persists
Software error An error has been detected in the
transmitter software.
Contact Emerson Process
Management Service Department.